Skip to main content

Troubleshooting

Start with the exact version, process and document. Keep private model paths, parameter values and credentials out of public reports.

The RevitThyme tab is missing​

Confirm full Revit 2027, Windows x64 and .NET 10 Desktop/Core x64 runtimes. Revit LT and other years are unsupported. Installation requires Revit closed normally; a running process retains loaded assemblies until restart. Review setup logs and the receipt. Do not delete unrelated add-in registrations.

The public installer is unsigned. Verify source/checksum and follow your organization's policy. Local development signing is a separate identity.

PowerShell cannot find rthyme​

Open a new terminal and inspect command precedence:

Get-Command rthyme -All

Aliases, developer snapshots or earlier machine PATH entries may take precedence. Use the receipt's absolute global_command path to identify the installed version. Do not overwrite unrelated PATH entries.

No session or the wrong document​

Confirm Revit is running with the matching add-in. Run rthyme sessions --json; normal discovery is %LOCALAPPDATA%\RevitThyme\sessions. Development runs have their own folder; use project.cmd dev-status -RunFolder $run.

Choose an explicit binding and inspect process start, document and view. Dead/reused processes and incompatible protocols are rejected. Upgrade add-in/CLI/MCP together. A pinned server cannot switch sessions. Never bypass failure by choosing a working model.

A capture is stale​

Model/view changes invalidate captures. Reinspect current values, but form a new edit only after any earlier operation is confirmed complete. Reopening a document creates a new identity.

An edit timed out or returned Unconfirmed​

Do not immediately submit a new write ID. Recover the original through MCP get_operation or CLI get-operation --session ABSOLUTE_FILE --request-id GUID --json. Inspect native values and request state. A timeout is not proof of rollback. Outcomes are session-retained; keep the session alive during recovery.

View Range refuses an edit​

Refresh in a floor, ceiling or structural plan. Controlling templates block edits. Revit validates plane order and special levels; ceiling plans look upward. More than 100 levels are refused. Plan regions and template editing are outside scope. See View Range.

Room Dimensions has no preview​

Use an enclosed rectangular room with four straight basic native walls on the view's level and phase. Linked, curved, slanted or irregular boundaries and split crops are unsupported. A rectangular crop must contain the whole room. Move a blocking tag or adjust clearance/inset; the tool never moves tags. Partial/duplicate/locked dimensions may need manual resolution. See Room Dimensions.

Agent sign-in or model access fails​

Connect Codex, complete browser sign-in, then Refresh. A runtime model listing is not an entitlement guarantee. Let Codex own authentication; never post credential files. See Agent state.

Website search is empty during development​

Search indexes are generated by a production build. In website, run npm run build, npm run check, then npm run serve to test search. Use npm start for editing. See website maintenance.

Still stuck​

Open a bug report with interface, toolkit version, exact Revit build when relevant, reproduction, expected/actual behavior and sanitized diagnostics. Prefer a minimal public sample to production models. Report security issues privately.